Search...
English

Elite Supersil Premium C18 - A New Generation Monodisperse Silica Microsphere Column Powered by Microfluidic Technology

In liquid chromatography, the column serves as the "heart" of the analytical process, directly dictating the accuracy, reproducibility, and efficiency of analytical results. For years, the core packing materials for high-end HPLC columns have been monopolized by a few manufacturers, leaving users grappling with premium pricing and long lead times.

Leveraging 30 years of chromatography expertise, Elite launches the Supersil Premium C18, a new-generation monodisperse silica microsphere column. It delivers outstanding separation performance without significantly increasing backpressure. Combined with the high loading capacity and scalability inherent to its fully porous silica structure, it provides a cost-effective alternative comparable to leading international products for applications in pharmaceutical, food safety, environmental monitoring, and beyond. This performance is powered by a disruptive manufacturing innovation: Elite's proprietary microfluidic technology.

I. Microfluidic Technology: Revolutionizing Column Manufacturing from the Source

Traditional column manufacturing generally relies on "one-pot" synthesis, which yields particles with a broad size distribution and poor batch-to-batch consistency. The process requires months of sieving to obtain particles of the desired size, resulting in significant material waste. Moreover, pore size control is challenging and often necessitates a cumbersome pore-swelling process. In contrast, Elite's proprietary microfluidic silica microsphere manufacturing technology confines the reaction within micron-scale independent spaces. Each microfluidic channel functions as a microscale reactor, where the silane precursor ratio is precisely controlled to achieve one-to-one conversion.

The core advantages of this technology include:

Extremely uniform particle size: Coefficient of variation (CV) < 3%, eliminating the need for sieving. The production cycle is only one week, with 100% conversion efficiency and zero waste, making it green and economical.

Precisely controllable pore size: The confined space of the microfluidic channels supports complex pore-forming systems, allowing direct preparation of silica microspheres with target pore sizes without subsequent pore-swelling steps.

Excellent batch-to-batch consistency: Parallel multi-channel scale-up ensures that every batch of media performs identically.

II. Performance Evaluation of the Supersil Premium C18 Column

Test Conditions

Mobile phase:            Methanol : Water = 85 : 15 (v/v)

Flow rate:                   1.0 mL/min

Detection:                  UV at 254 nm

Injection volume:       10 μL

Under the above chromatographic conditions, the Supersil Premium C18 column and two newly purchased, same-specification columns from imported brands (labeled as S and M) were used to separate a mixture of uracil, acetophenone, toluene, ethylbenzene, and fluorene. Figure 1 shows the chromatogram obtained with the Supersil Premium C18 column. Table 1 compares the column efficiency for the five compounds across the three columns.

Figure 1. Chromatogram obtained with the Elite Supersil Premium C18 column (Peaks: 1-uracil, 2-acetophenone, 3-toluene, 4-ethylbenzene, 5-fluorene)

Compound

Supersil Premium C18 Column Efficiency (N/m)

Brand S Column Efficiency (N/m)

Brand M Column Efficiency (N/m)

Supersil Premium C18 Advantage

Uracil

73,028

46,544

33,100

56%~121% higher

Acetophenone

87,616

60,540

47,664

45%~84% higher

Toluene

103,968

76,460

67,712

36%~54% higher

Ethylbenzene

107,136

76,660

71,036

40%~51% higher

Fluorene

111,748

77,172

70,968

45%~58% higher

Table 1. Comparison of Column Efficiency for Three Columns of the Same Specifications

As shown in Table 1, under identical test conditions, the Supersil Premium C18 significantly outperforms the two same-specification commercial columns for all five compounds, with a remarkable 45%~58% improvement for the difficult-to-separate compound fluorene.

III. Rigorous Pharmacopoeia Application Cases: Resolution and Tailing Factor Fully Meet Requirements

The Supersil Premium C18 demonstrates excellent performance in the analysis of multiple pharmacopoeia-listed substances. Typical application examples, along with chromatograms and key data, are presented below.

Warfarin Sodium (Chinese Pharmacopoeia Method)

Figure 2. Supersil Premium C18 chromatogram for warfarin sodium system suitability test (Peak 1: 4-hydroxycoumarin; Peak 2: benzylideneacetone; Peak 3: warfarin sodium)

Table 2. Supersil Premium C18 System Suitability Data for Warfarin Sodium

Compound

Retention Time (min)

Theoretical Plates

Tailing Factor

Resolution

Pharmacopoeia Requirement

4-Hydroxycoumarin

3.616

16,295

1.20

Benzylideneacetone

6.418

20,372

1.05

19.12

10.0

Warfarin Sodium

8.755

17,302

1.00

10.48

5.0

The Chinese Pharmacopoeia requires that in the system suitability test for warfarin sodium, the number of theoretical plates calculated for the warfarin sodium peak should be no less than 2000, the resolution between the 4-hydroxycoumarin peak and the benzylideneacetone peak should be no less than 10.0, and the resolution between the benzylideneacetone peak and the warfarin sodium peak should be no less than 5.0. The results demonstrate that the Supersil Premium C18 column provides a stable baseline, symmetrical peaks, and complete separation, fully meeting the pharmacopoeia requirements.

Lansoprazole (Chinese Pharmacopoeia Method)

Figure 3. Supersil Premium C18 chromatogram for lansoprazole system suitability test (Peak 1: Degradation product 1; Peak 2: Degradation product 2; Peak 3: Lansoprazole)

Table 3. Supersil Premium C18 System Suitability Data for Lansoprazole

Compound

Retention Time (min)

Theoretical Plates

Tailing Factor

Resolution

Pharmacopoeia Requirement

Degradation Product 1

6.532

13,129

1.05

Degradation Product 2

8.601

13,641

1.08

7.92

>3.0

Lansoprazole

10.808

14,332

1.06

6.74

>3.0

The Chinese Pharmacopoeia requires that the resolution between lansoprazole and its two major degradation product peaks be greater than 3.0 in the system suitability test. The results confirm that the Supersil Premium C18 meets the pharmacopoeia requirements.

Summary of Other Application Cases

As shown in Table 4 and Figure 4, the Supersil Premium C18 column consistently delivers excellent separation efficiency, symmetrical peak shapes, and reliable resolution across various pharmaceutical analyses, meeting and exceeding pharmacopoeia and routine quality control requirements.

Table 4. Supersil Premium C18 System Suitability Data for Multiple Drugs

Drug

Compound

Retention Time (min)

Column Efficiency (N/m)

Tailing Factor

Resolution

Pharmacopoeia Requirement

Nisoldipine

Impurity I

14.077

18,812

1.00

 

Impurity II

17.181

18,912

1.00

6.82

 

Nisoldipine

18.730

18,042

1.02

2.93

Resolution ≥ 1.5

Doxofylline

Theophylline

4.375

18,045

0.96

 

Doxofylline

10.354

21,369

0.95

28.92

Resolution ≥ 1.5

Capecitabine

Impurity I

3.065

14,463

1.11

 

Impurity II

3.365

14,487

1.14

2.84

 

Capecitabine

19.045

66,938

0.89

77.21

Resolution ≥ 1.5

 

Impurity III

21.088

79,744

1.82

6.89

Aripiprazole

Impurity I

17.476

15,151

1.09

 

Impurity II

33.755

17,341

0.97

20.44

 

Aripiprazole

44.062

22,214

1.20

9.34

Resolution ≥ 1.5

 

Figure 4. Supersil Premium C18 system suitability chromatograms for (A) nisoldipine, (B) doxofylline, (C) capecitabine, and (D) aripiprazole.

All results presented above, from column efficiency comparisons to pharmacopoeia system suitability tests, demonstrate that Supersil Premium C18 consistently delivers outstanding performance, reproducibility, and reliability required for demanding applications. It is not only a manufacturing innovation, but also a truly powerful chromatography "heart".

Share to:
Contact us
×
* Required field
Thanks
Your info had been submitted.
Site Search
Find products, applications, and technical resources